Portfolio MALDI-TOF Mass Spectrometry

Pulse aquí

The MALDI-7090TM is targeted for proteomics and tissue imaging. It combines Shimadzu’s extensive MALDI TOF-TOF mass spectrometry expertise with novel patented technology to provide ultimate performance in identification and structural characterization of biomolecules.

MALDI-7090 sets a new benchmark in MALDI TOF-TOF design:

  • Market leading MS/MS resolution
  • Proprietary solid state UV laser technology
  • Ultra Fast acquisition speed in MS and MS/MS
  • Integrated 10 plate loader
  • Newly designed MALDI SolutionsTM software

    Read More

    Pulse aquí

    The MALDI-8020 is the latest in a long line of MALDI-TOF products from Shimadzu. This benchtop, linear MALDI-TOF mass spectrometer delivers outstanding performance in a compact footprint, making it an ideal choice for today’s increasingly demanding laboratories.

      Read More

      Pulse aquí

      The AXIMA Performance is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and higher confidence in identification. It is an extremely versatile and powerful TOF-TOF system, integrating workflows for a diverse range of analytical needs.

      • From high energy MS/MS of proteomics and other biological and organic samples to uncompromised analysis of high mass intact proteins
      • True high energy MS/MS – CID with a laboratory frame collision energy of 20keV
      • Optimal precursor ion selection resolution using revolutionary gating technology
      • Outstanding sensitivity – uncompromised design, to ensure no MS/MS signal is discarded

        Read More

        Pulse aquí

        • Powerful MALDI-TOF performance for reliable mass information and MS/MS derived structural detail.
        • Linear mode allows the interrogation of high molecular weight samples, whilst reflectron mode, incorporating the patented curved-field reflectron (CFR), provides the high resolution and mass accuracy necessary for successful proteomics and life science experiments.
        • High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.
        • An affordable robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.
        • Excellent sensitivity is achieved using near-axis laser irradiation and advanced ion optics for enhanced ion transmission.
        • MS/MS may be easily performed using a seamless approach – ions of interest can be isolated using a precursor ion selection device, incorporated as standard, and data-rich fragment ion spectra quickly and simply acquired.The newly improved curved field reflectron design augments the low mass fragment region providing useful additional information.

          Read More

          Pulse aquí

          • Linear MALDI-TOF mass spectrometry for reliable mass information.
          • An affordable, robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.
          • High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.

            Read More